  1. engggu

    SMOKE EXTRACTION

    Hi Experts, is it required to have a smoke extraction at ground floor given it has a pressurize fire exit corridor and near the exits
  2. engggu

    Queries on Equipment Selection

    Good day Experts! I am currently designing a residential VRF system. Since the required indoor temperature is 21C, resulting airflow computed ranges between 600-650 cfm/ton. Basically, if I select an indoor unit @ medium speed, it will require me to select at 2-3 capacity higher than the...
  3. engggu

    Generator Sprinkler Temperature Rating Requirement

    Dear Experts, Do we have any sprinkler temperature color coding or requirements to be installed with Pre Action System for generator room. Thank you.
  4. engggu

    IDF CABINET/ROOM

    Good Day Experts! Is it required to have sprinkler protection for a 0.9mx0.9 IDF room/cabinet with fully louvered door? Thank you. Mark
  5. engggu

    FRP MODULAR TANK AND STEEL CYLINDRICAL TANK

    Hi experts, do we have limitation in terms of capacity for FRP modular tank used for fire protection system. One from our team sited that if it is 50 cu.m or more, it should be steel cylindrical tank from OSHA standard.
  6. engggu

    FIREMANS LIFT LOBBY/VESTIBULE

    Hi Experts, the electrical room is adjacent to the firemans lift lobby and the access is also located in the said lobby, will it have any violation on the code?
  7. engggu

    HAP QUERIES

    Hi moideen, just in case it will also affect the wall and other thermal loads? Thank you
  8. engggu

    HAP QUERIES

    Hello experts, i would like to ask if there is an option to change the actual temperature of outdoor air i supplied to the coil? Is there any options from HAP? Currently, hap assuming the outdoor temp from the weather as entering air temp of outdoor air. Thank you
  9. engggu

    Fire Service Elevator Lobby

    Hi. This is a high rise office building
  10. engggu

    Fire Service Elevator Lobby

    Do we have specific or minimum requirements regarding the size of the door for the lobby of fire service lift? Thank you
  11. engggu

    NFPA USE OF QUICK RESPONSE

    HI EXPERTS, May I know if the use quick response sprinklers are required for the residential areas like condominiums? Or standard sprinklers can also be used on the dwelling units. Thank you
  12. engggu

    PIPE SLEEVING

    Hi Experts, do we have pipe sleeving standard sizes as per NFPA 13? Thank you.
  13. engggu

    Building Pressurization

    Thank you very much experts
  14. engggu

    Building Pressurization

    Hi experts, For an office building, do we have a rule of thumb or recommended percentage for the pressurization? Say outdoor air 5% higher than the exhaust? thank you
  15. engggu

    REF PIPING

    Thank you very much
  16. engggu

    REF PIPING

    Hi experts, Do we recommend embedding ref pipe on the walls? For aesthetic purposes
  17. engggu

    MCC ROOM

    Hi Experts, is 8sqm/ton more than enough for a MCC room located at a tropical country
  18. engggu

    Fire Hose Valve Connection and Aux Drain

    Hi Experts, Seeking advise if using threadolet instead of tee reducer for the connection of 65mm hose valve to 150mm riser is permitted? And also using of alarm test module (1 alarm test module, 1 union patente) instead of conventional aux drain(3 valves, 2 union patente, 1 sight glass) Thank...
  19. engggu

    Sprinklers Under Parking Access Ramp

    Is there a code exemption on provision of sprinklers for space under a parking access ramp? Thank you experts!
  20. engggu

    Cross Main pipe passing thru Server Room

    Thank you very much!!