all above clarifications & suggestions are very helpful, I am now compiling my writeup to present it to the client.
Having gone through the MSS-SP-44 Cl. 5.3 Hub Design & 5.4 Welding End, its clear to have same pipe & the flange IDs.
Here in case, Figure 2'Bevel Detail for Wall...
your response is appreciated, LittleInch.
F60 can't be procured as its not easily available in market, this being a shutdown activity, the lead time for F60 is also very high.
Given the situation, I find it difficult to convince the Client. Here I am looking for some solid technical...
Dear experts,
A situation regarding the subject matter has emerged within a project, I am working on.
As proposed by the contractor, an API 5L Grade X52 pipe( 18", Sch 40) needs to be reviewed regarding it's compatibility with the ASTM 105 Flange (instead of ASTM A694 F60 Flange.