Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Tek-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. drillhouston

    Well Test

    John, You can use the RedEye water-cut meter (Near Infra Red technology) to measure the BS&W in the liquid leg of the 2 phase separator. This meter has great accuracy in the higher water-cut range and works in the 0-100% water-cut range. Now, you would also need a flow meter (turbine meter...
  2. drillhouston

    Online Handbook

    Thanks BigInch. This is very helpful. Thanks for sharing. DrillHouston
  3. drillhouston

    GVF; GOR & GLR units?

    Thanks dhayes, I really appreciate the quick calculation you have done. Just to add to your reply the "460" value in the aove calculation is to convert F to Rankins. For our water-cut metering we really need to understand the GVF to understand the application and lot of times the operators...
  4. drillhouston

    GVF; GOR & GLR units?

    Thanks for GVF & GLR/GOR units clarification, Sebasmagri & dhayes!! It was interesting to know from Sebasmagri as to why do we need GOR/GLR ratios for reservoir engg. purposes treating gas & liquids separately. Here is the information I have: Liquid (oil+water) rate = 26500 bbls/d Gas rate =...
  5. drillhouston

    GVF; GOR & GLR units?

    Hi, If some one can give me an insight into this will be very helpful. Part 1: GVF = gas void fraction - what are the units for GVF (% or MMCF/BBls)....I am confused!! Definition for GVF is (Gas volume)/(gas+oil+water); now the question is if GVF is defined in (%) what units do we take the...