  1. generatorlabs

    Solar Disconnect Dilemma

    I am prepping to do the preliminary work on a Solar Panel install. The install is straight forward. 16 Panel array with micro-inverters on each panel. The micro-inverters are intelligent and use weather rated, summing cables to string all the units to a final junction box on the roof. I will...
  2. generatorlabs

    Why not use integrated contactor Aux contacts for making a reversing contactor set?

    @itsmoked: I agree with what you are saying about the possibility of a tech manually pushing the contactors in and causing a dangerous short.....I will admit that I have participated in such stupid acts :) But here is why i brought this up to begin with. ABB sells two snap-on interlock units...
  3. generatorlabs

    Why not use integrated contactor Aux contacts for making a reversing contactor set?

    I have looked at a few videos that use ABB IEC-frame contactors to assemble a reversing contactor set and the preferred method of interlocking is using a hybrid, modular, electromechanical interlock like the VE5-1. A perfect example of such a video can be seen on you tube if one does a search...
  4. generatorlabs

    Is time delay required when switching from LO to HI speed on 3 phase, two winding motor?

    Thank you all for your very informative replies. I think I can proceed safely with my automation project now that I have some solid images I can reference. I tried to explain this to my industrial rep at Galco and he was baffled by it. I then pointed them to an image of the Dahlander motor...
  5. generatorlabs

    Is time delay required when switching from LO to HI speed on 3 phase, two winding motor?

    @ electrolitic "The shorting contactor shall be closed always in advance" Should I still insert a short timer between when Lo Speed contactor releases and Hi Speed shorting contactors pull in? Even though there are interlocks preventing both from occurring at the same time I was just wondering...
  6. generatorlabs

    Is time delay required when switching from LO to HI speed on 3 phase, two winding motor?

    Thank you all for your replies. I have attached a photo. Please help me validate if what I am reading on the prints is correct. Is that a shunting contactor? What function is it performing? I see there is a consensus on inserting a short delay to allow circuits to stabilize. From what I...
  7. generatorlabs

    Is time delay required when switching from LO to HI speed on 3 phase, two winding motor?

    Working on replacing a starter on an abandoned warehouse. The starter is basically destroyed and missing major parts. The motor is a 5 hp, two winding, 3 phase motor, running at 480. The starter will be reversible. The motor is being rewound. I have not worked on a separate winding motor before...