Greetings Adrian and all,
There is no displacement limiter on the pump.
You have rightly pointed out that the pump is responding to its own pressure as it is being dead headed. By closing the discharge valve and deadheading the pump, I was simulating the neutral position of closed centre...
Hello Adrian and others,
Please give me some Engineering tips on this issue again.
I have this A10VSO pump that is used to power a closed centre hydraulic machine with multiple actuators (pistons and motors) operating at 2500 psi. The pump was recently replaced and I believe has not been set...
Thanks Adrian, for your response.
For the LS line, do I need to introduce an additional orifice or will the orifice built into the X port of the 'margin compensator' suffice?
If there is to be an additional orifice, can it be on a branch line Tee'd off from the main pump discharge?
Seeking guidance on controlling a Rexroth A A10VSO variable displacement pump.
I have this A10VSO pump that is used to power a closed centre hydraulic machine with multiple actuators (pistons and motors) operating at 2500 psi. The pump was recently replaced and I believe has not been set up...