Maslov,
It is a studding outlet and a standard B16.5 Blind however we apparently are lacking a certification from the company that made it stating they can make standard B16.5 blinds. the AI opening the job wants a UG34 calculation (in leu of a certificate) on the blind to prove it is...
Hello, Very new to pressure vessel design. Our AI has asked for UG-34 calculations on a manway blind. based on its type the UG-34 calculations button that usually is available is not for this opening. I have tried to just read the book and do the calculations by hand but I don't understand which...