    Roof Gable drag truss with no diagonals

    Yep, I can provide the sheathing in lieu of the truss diagonals, was just surprised their drawings and response indicate is is fine as a drag truss with just the verticals, top & bottom chord.
  2. msdmoney

    Roof Gable drag truss with no diagonals

    Reviewing a shop drawing for a drag truss that I specified at the gable end. Therefore it has the verticals, but I am accustomed to seeing diagonals as well to transfer the horizontal component, otherwise assuming the verticals as two force members, all the horizontal load has to go through the...
  3. msdmoney

    L-shaped Retaining Wall (no toe) and "J"-shaped retaining wall (no heel) joint detailing

    The Wight and MacGregor concrete book gives a really good explanation on the direction of hooks in chapter 17, Section 17-12, not directly in regards to retaining wall, but with regard to Beam-Column Joints. It goes into opening and closing corner joints, and (it does reference retaining walls...
  4. msdmoney

    Stepped Foundations and Shearwalls

    I agree about leaving the window since everything is transferring in shear to the concrete through the drag, but the vertical chord holdown above this header (from the left side of the perforated) would need to transfer to the header and then have a holdown on either side of the header that goes...
  5. msdmoney

    Pile Design

    I understand what you mean when you say he used enercalc to design the concrete column. I usually use spcolumn for the same purpose, essentially to build the PM diagram for the column. Most concrete texts will go through the process for this by hand. What I don't follow though is the use of...
  6. msdmoney

    D.5.2.9

    Agree pretty much with what Kootk wrote. Similar to what you wrote above about the transfer of forces, I've always thought of the reinforcement keeping the chunk of concrete from pulling out because it is crossing the potential concrete failure surface and developing above and below. This...
  7. msdmoney

    L-shaped Retaining Wall (no toe) and "J"-shaped retaining wall (no heel) joint detailing

    I've been working through some retaining wall details for a project that requires a condition with a footing without a toe and a footing without a heel. I'm curious on how others detail the wall to footing joint. For a T-shaped footing, I typically detail per the CRSI manual, developing the...
  8. msdmoney

    Wood Exterior Non-Bearing Wall in Steel Building

    In a building with metal stud exterior non-bearing walls I've always provided either a slotted drift track (vertical slots in the flange, horizontal slots in the web) to accommodate beam deflection and in plane drift or a nested track assembly. For a building with exterior, non-bearing wood...
  9. msdmoney

    Maximum absolute deflection in a ridge beam

    Thanks for the responses, the roof is an existing cedar shake roof that they intend to leave in place with no plywood so I can't assume that the roof acts as a folded plate. Definitely going to design a new structural ridge, just wanted to get input on what others use for an absolute deflection...
  10. msdmoney

    Maximum absolute deflection in a ridge beam

    I have a project with an existing ridge board and rafter ties, where the client wants to cut out the ceiling/rafter ties to vault the ceiling. The plan is to install a ridge beam that spans approximately 30 ft to support the existing roof. I'm just wondering if anybody typically limits the...
  11. msdmoney

    ASCE 7-05 OR 7-10?

    I agree with JAE's summary you always use the reference standard as referenced in the code. I had some long term projects that were still using outdated referenced standards by the time they finished construction. But you wouldn't want to suddenly jump forward in referenced standards, could...
  12. msdmoney

    Books on Structural dynamics?

    Also used Chopra's book in school and it is the book I would recommend.
  13. msdmoney

    Wood Infill in Existing Masonry

    I'm designing a wood infill wall in an existing masonry building opening. I was going to detail the top to accomodate deflection via a metal slip track (similar to metal studs, not sure how common this is), do most people leave a gap the sides of the wall as well, or just detail the wood tight...
  14. msdmoney

    CMU Arch in Existing Wall and CMU infill

    I have a couple questions on a project I am working on, looking to get some feedback on a some options. 1) I am designing a new opening that is being cut in an existing wall. The door is approximately 12' wide by 14'-6" tall, the 14'-6" being the top of arch with a 3' rise. Looking at options...
  15. msdmoney

    Continuous Footing in expansive soils

    I am designing a residential foundation on potentially expansive soils. The geotech report gives recommendations for conventional continuous and spread footings, and also gives a differential deflection value of 1" in 30 ft. Is the typical method of analysis for this condition to compute the...
  16. msdmoney

    Inryco 3"W22 Metal Deck

    Does anyone have any information on Inryco 3"W22 metal deck. I'm working on an existing project from 1982 that specifies this and I can't find any reports or literature available online for this deck type. I also tried calling Inland Buildings, but it is a totally different company now and I...
  17. msdmoney

    Boundary Post and Sheathing at T-Intersection

    Thanks for the reply, I've more done gobs of steel and concrete rather than wood so it helps to get some extra perspective. My inclination is to do what you suggested, to me it would be akin to the break in the panel joints as long as the interconnection between the last post and the boundary...
  18. msdmoney

    Boundary Post and Sheathing at T-Intersection

    I'm looking at the detailing for an interior wood shear wall at a t-intersection with the exterior wall. The typical detail is the California framed intersection but that doesn't allow the sheathing to continue through. I'd like to bury my boundary post in the exterior wall and then continue...