Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations KootK on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. asmeqc1

    Can you have joint efficiency of 1.0 on a spot radiography joint per uw-11(a)5(b)?

    Nevermind, just answered my own question. Turns out yes, a type-1 joint using spot radiography can indeed be type 1, which might throw you off if you were looking at the table in uw-12 which says its 0.85. This is why. UW-12(d) states: "For calculations involving circumferential stress in...
  2. asmeqc1

    Can you have joint efficiency of 1.0 on a spot radiography joint per uw-11(a)5(b)?

    Hey everyone, I have a question about joint efficiency. Take the case of a vessel with an elliptical head attached with a type 2 joint that meets spot radiography requirements per UW-11(a)5(b). The vessel also has a single longitudinal joint and all Cat A welds are type 1 with full radiography...

Part and Inventory Search