Please refer calculation of a body flange given below from PV Elite:
ASME Maximum Circumferential Spacing between Bolts per App. 2 eq. (3) [Bsmax]:
= 2a + 6t/(m + 0.5)
= 2 * 24.000 + 6 * 62.000/(2.00 + 0.5)
= 196.800 mm Maximum Bolt Spacing Exceeded !
For vessels in lethal service or...
Hi...
I am designing an AJL type R class exchanger.
I have two questions
1) When I enter body flange dimensions (this is a non-standard flange) with hub dia and length equal to zero, the software says wrong geometry.