Here is a picture of the error and a sample edge flange part http://files.engineering.com/getfile.aspx?folder=0761aefe-9bc2-4cc4-8a5d-7e22b92c3b14&file=Error_Gauge_Table.png
Here is my sheet metal part
Doing Workhttp://files.engineering.com/getfile.aspx?folder=ab7a1926-07c2-4e16-895c-c6c55b2b8549&file=MAIN_PANEL^MILLENIUM_RINSER_GUARD.sldprt
Hello all,
I am having an issue with using the gauge and bend tables. I get an error saying "The radius of the bend fell outside the bend allowance/deduction table. The bend allowance is calculated using the k factor instead". I have made sure my tables are correct and have tried all different...
Awesome Cockroach!
I just did a similar method to this except with just a point load in between the two bearings. I shall look over your calcs, I know need to review my basic statics, too much time spent away Thank you.
Hello,
I have this axle part of a wheel assembly and need some basic hand calculations done on the axle. I attached a outline of the picture of the problem. I was thinking of treating this like a round bar and calculating the max deflection and comparing that with a computer simulation. How...
I've been looking into explosion proof enclosures myself. Are you looking for a certain rating nema or specific class groups?
I've found some for my purpose from adalet, killark, akron electric...
Doing Work
Hello,
I have a question about using NH3 for aluminum kovar brazing. What would be the difference in using NH3 rather than nitrogen or nitrogen/hydrogen in the furnace?
Doing Work
I am researching possible parameters that could be affecting the quality of our heat treated products and am interested in inline continuous furnace processing rather than batch processing. Is there any concern with possible contamination from the metal belts being used in these inline conveyer...
Can a computer PC system be installed onto a belt furnace for temperature control and profiling? How much work/cost would that take?
Sorry for the broad question, still in the early planning stages.
Thanks in advance!
Thanks All! Some more info on this, the resistor will be running for 20 minutes tops and will be in its own enclosure, so we're thinking of using a larger aluminum enclosure and use the breathers that DRweig suggested.
Doing Work
Hi,
Any help is appreciated and thanks in advance.
We have a large brake resistor inside an enclosure and we're thinking of adding a fan inside for cooling because the inside can reach temperatures as high as 70-80 celcius.
The problem is that explosion proof enclosures usually don't have any...
I do like the combination of art and engineering into projects I do. It makes it feel more personal and unique which is why Times New Roman rules, haha just kidding
Doesn't the higher temperature zone affect the lower temperature zones though?
For example, the 500C zone will cause changes to the 150C zone. Also, How well can the temperature in the zone be controlled?