  1. redtiger

    Cross-Grain Bending in wood members, Ledger

    XR250, The h8 are at 16" on center and there is a note stating that the studs must align with the roof joist. Regarding the sheating along the back of the parapet (the right side of the stud, per the sketch), I don't quite follow your shear load pad. Lets say that your diaphragm's shear at...
  2. redtiger

    Cross-Grain Bending in wood members, Ledger

    PittEng88, I can do that, but my concern is attaching the parapet wall to the structure without using knee braces.
  3. redtiger

    Cross-Grain Bending in wood members, Ledger

    Hello, I am designing a wood structure that has a 3'-6" parapet. Im using a 2x ledger to support a top mounted hanger that ultimately suppors the joist. A 2x blocking is provided to transfer the diaphragm shear into the shearwall. Should I consider cross grain bending, I am not using bolts...
  4. redtiger

    Vaulted Ceiling End rafter

    First image looks blurry, let me try again. Thankshttp://files.engineering.com/getfile.aspx?folder=128dc442-b4df-460d-afb8-4aaf2694a921&file=Screenshot_20180319-215009.jpg
  5. redtiger

    Vaulted Ceiling End rafter

    Hello Guys, Im working on a remodel where we are installing an interior ridge beam, please se the attached image. My main concern is attaching the end rafter to the knee wall. Have you guys done something similar? Thank you...
  6. redtiger

    Discontinuous chords in wood framed building @ dormers

    JAE, here is a sketch for the diaphragm. I see the ridge beam acting as a chord with the north to south loading. Im having difficulties when I reverse the load. It seems that half of the roof (dormer side) is cantilevered and just goes for a ride north. Regards.
  7. redtiger

    Discontinuous chords in wood framed building @ dormers

    Thank you Kootk, I will explore your second alternative. Thank you JAE, Im still trying to digest the idea of only using one side of the roof and ridge beam as a chord.
  8. redtiger

    Discontinuous chords in wood framed building @ dormers

    Hello, I am working on a new wood framed building. There are several dormers where the double top plate will have a discontinuity. Please see the attached sketch. Based on diaphragm design, the chord force is around 2.5 kips. My question is the following, how do I connect the plates at...