  1. SMcI

    Brasil-Pressure Vessel Approvals

    Thank you very much victorpbr, I am very grateful for your advice. My next challenge is to find a licensed engineer.. Thank you.
  2. SMcI

    CGA S 1.2 - U value for superinsulated cryogenic vessels at "Fire" conditions 649 Deg C

    This is what I am sizing relief valves for at the moment - LOX tanks. I have some information which has been passed down over the years, albeit from one of the big gas companies here in the UK, but is very old and it does not provide values for the elevated temperatures as required by S 1.2...
  3. SMcI

    CGA S 1.2 - U value for superinsulated cryogenic vessels at "Fire" conditions 649 Deg C

    Thank you too EdStainless. I will look to see if there is any guidance provided in the form of CGA documents. In terms of the outgassing, the S 1.2 standards requires that the calculations are carried out for the condition of loss of vacuum with fire engulfment. Which is pretty onerous, but...
  4. SMcI

    CGA S 1.2 - U value for superinsulated cryogenic vessels at "Fire" conditions 649 Deg C

    Thank you. I assumed 660 deg for melting point of aluminium. I wondered if the 649 deg was somehow chosen for this reason? I am aware we are very close to the melting point but wondered if the multiple layers of separating layers would keep the insulation in place and reduce heat transfer to the...
  5. SMcI

    CGA S 1.2 - U value for superinsulated cryogenic vessels at "Fire" conditions 649 Deg C

    I would be very grateful if someone could tell me if they have a value for "U" as described within CGA S1.2 "Pressure relief device standards part 2 - Cargo and portable tanks for compressed gases" cl 6.3.3. for super insulated cryogenic vessels. The insulation system consists of approx 35...
  6. SMcI

    Brasil-Pressure Vessel Approvals

    Thank you very much XL83NL and Victor. Both of your posts are a great help. I am very grateful. If you could give me some advice on where to look to find the ART agreements I would also be grateful. Thanks you.
  7. SMcI

    Brasil-Pressure Vessel Approvals

    I am new to this forum, please forgive me if my format is wrong. I am hoping someone can tell me if there are any regulations in existence for approval of pressure vessels for use within Brasil. I have read Brazilian NR13 "Boilers and Pressure Vessels" but find it more along the lines of...