the 10 gpm is the slow feed a rapid feed pump of 100 gpm is used to get to the bottom or top
the slow feed is for actuall drilling
rod size of 4" stroke 30 ft
but that shouldn't be relavent
can you explain both ways the cheaper one as well as the more acurate way
Hi
I have a drill rig that has a rotational head
the head moves up and down and holds/raise/lowers the head
the head has varible weight and needs to travel up and down at different rates and also different total pressures
the basics are as follows
10gpm 3000psi gear pump
directional control...