  1. mamoore

    Nitrile Isolator Creep

    This is an application of using Nitrile blocks as foundation shock absorbers; the type of application one would see in a seismically active area. My question concerns Nitrile and how its shock absorbing (static and dynamic spring constants) change with time. Questions: I understand there...
  2. mamoore

    High Temperature Non-Conductive Pipe

    Problem: High temperature exhaust system routed through an electrically sensitive area. Need a 30' horizontal section of non-conductive piping material (such as refractory)that will be connected up to 24" diameter carbon steel exhaust pipe on either end. 30' section requirements: -...
  3. mamoore

    Diesel Engine Exhaust Corrosion

    Thanks for the input Metalguy, Hacksaw, and Martinwhelan. I wanted to clarify the primary concern with this exhaust system is condensation of diesel exhaust gases on carbon steel due to the extreme length of piping. Insulation is placed on the outside of the pipe only and no coatings are...
  4. mamoore

    Diesel Engine Exhaust Corrosion

    Proposed System: 1825 kW standby diesel power plant with very long horizontal exhaust pipe and vertical stack. Specifications: Would like pipe to be std wt. carbon steel to keep costs down. Pipe is insulated with 6" mineral wool. Engines will be execrised at 50% load once a week for...