Hello
I put body flanges between top head and shell .
In compress , this message shows to me:
" body flange is being counted as a line of support for external pressure "
Anybody explain to me this and how I fix it ?
Thanks ?
Hello
I have one shell ( seamless pipe ) with two dished end.
The top head has to be joint with shell with #150 WNRF Flange .
The thing is in compress If I use ASME B16.5 Flange I cannot put Two flanges bolted together in top. I can put only one .
I can do this only If I use Appendix 2...
I have one vessel with seamless pipe and pipe cap head . The vessel has inside demister so client has requested that top head to be provided with flanged joint . How I do this in compress ?
Hello
I am fresher for pressure vessel design .
If MAWP is limited by flange ( class#150 ) and client has no issue with that since they do not want to change it to 300# , can I do wrc analysis 297 in this case to verify shell thickness ( If MAWP is limited by flange ) ???