RVAmeche,
Thank you for the quick response.
Autopipe results on the report show that the Code allowable values are four (4) to twenty (20) times of the code stresses. Considering these values and that the properties are about 10% different, can we safely say that all fine for the system?
Hi Guys,
Recently there was Stress analysis study prepared on the Asphalt loading system I am working on. The analysis considered a specific brand /properties of Single expansion joint in their calculation. However during the procurement, a different brand was selected and thus properties are...
Hi Guys, Does anyone here have an experience on installing a hot oil tracing for a 1 km pipe used for bitumen transfer? I understand that for pipelines as long as these electric tracing is the way to go but is it really worth considering to install hot oil tracing instead? If yes,are there...