  1. Davidson84

    NFPA 850 fast depressurization systems

    Hi NFPA 850 established fast depressurization system like a mechanical passive system designed to depressurize the transformer a few milliseconds after an occurrence of an electrical fault. Currently there are several systems to avoid transformers explodes like: Sergi, Sentry, CTR, Jiangsu among...
  2. Davidson84

    NFPA 850

    Thanks a lot dont try, do it!
  3. Davidson84

    NFPA 850

    Alright, but it is feasible to make this kind of tests t FM? dont try, do it!
  4. Davidson84

    NFPA 850

    Hi, I need to know if the Electrical Hazards Laboratory or any facility of FM can test an explosion prevention system for a transformer. Specifically a destructive test in order to prove effectiveness of and passive mechanical system according to NFPA 850 recommendations. Thanks for your help...
  5. Davidson84

    NFPA Fire Protection Handbook

    ok guys, thanks anyway! dont try, do it!
  6. Davidson84

    NFPA Fire Protection Handbook

    Actually I need the entire document, tks for your help! dont try, do it!
  7. Davidson84

    NFPA Fire Protection Handbook

    Does anyone have NFPA Fire Protection Handbook, 20th edition. (PDF), please do share to me on dajar1984@gmail.com dont try, do it!
  8. Davidson84

    fast depressurization system

    Hi NFPA 850 established fast depressurization system like a mechanical passive system designed to depressurize the transformer a few milliseconds after an occurrence of an electrical fault. Currently there are several systems in market offering this kind of working but I realized that some of...
  9. Davidson84

    Does NFPA permit Underground Conrete Fire Water tanks

    According to my knowledge: maintenance cost and time of vertical turbine fire pump are significantly greater than using a centrifugal fire pump. so if money or terms is an important issue,the best choice is CP. dont try, do it!
  10. Davidson84

    Transformer area calculation

    Thanks Guys for your comments, actually I'm checking some data sheets about blast preventing systems for oil-isulated outdoor power transformers, I dont have so much time working on Fire prevention in my job, but this forum has been very useful as long as I've been studing the NFPA standard...
  11. Davidson84

    Transformer area calculation

    Actually is an outdoor oil-insulated transformer... dont try, do it!
  12. Davidson84

    Transformer area calculation

    Im designing a deluge system for a 230 kV transformer in a electrical power station, at the moment of calculate area of transformer NFPA 15 suggest the following: "The water shall be applied al a net rate not less than 0.25 gpm/ft2 of the proyected area of a rectangular prism envelope for the...