Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: Tothesky
  • Order by date
  1. Tothesky

    Vent hole for re-pad inside the vessel

    For High Temperature Operation, All Internals' Reinf. Pads have Vent Hole as mandatory. If you don't make Vent Hole, Reinf. Pad Inside will be sealed perfectly. During Operation,High Temperature will expand Air inside Reinf. Pad due to Heat. Finally, The Expanded Air will break Welding between...
  2. Tothesky

    Manhole size per Asme VIII

    SEE ASME SEC. VIII APP.2 AND UG-34. OR CLIENT ACCEPTS OTHER CODE OR STANDARD, YOU CAN USE 'JIS CODE' ( <--- JAPANESE CODE.) IN ASME, MIN. FLANGE RATING IS 150 PSIG ( 10.5 KG/CM2G). BUT, JIS CODE PROVIDES FLANGE RATING BY 5 KG/CM2G. REGARDS, MOON.
  3. Tothesky

    Water cooling HE

    Normally, Water Cooling need smaller heat transfer area than Air Cooling. The Heat Transfer Coefficient of Air is smaller than that of Water. Best Regards, Moon
  4. Tothesky

    HEX end cap divider plate vibration

    Is there NO Groove for Passpartition Plate(Divider Plate) on Tubesheet? Passpartition nornally to be inserted to groove on tubesheet. The deep of groove is 5mm from surface of tubesheet. Moon.
  5. Tothesky

    Studded Outlet per Section VIII Div. 1

    Applicable Materials of ASME are listed in ASME Code. For example, See 'UCS-5' and 'Table UCS-23' for Carbon & Low Alloy Carbon steels in ASME SEC.VIII Div.1.
  6. Tothesky

    How to design Liquid Receiver Tank?

    Dear MJCronin, For Continuous Blowdown under Steady State, it's very small. I have experienced already. But, for Intermittent Case (Non Continuous Blowdown)under Non Steady State, we should take account carefully. This is only my simple opinion. Moon.
  7. Tothesky

    How to design Liquid Receiver Tank?

    Right! And, I fully understand! For Condensate Receiver under steady state condition, I will consider The worst condition with considering many cases of Operating Conditions. And, I confirmed that The condensate receiver is Buffer Tank. For Intermittent Receiver under Non-Steady state...
  8. Tothesky

    How to design Liquid Receiver Tank?

    Thank you for your confirmation. As per your request, I try to inform you more. Condensate Tank under Steady State Condition : The Condensate Receiver Tank is to take condensates from other process equipments. After taking Condensates, These condensates move to next process such as Boiler etc...
  9. Tothesky

    How to design Liquid Receiver Tank?

    I need Engineering Practice for Design of Receiver Tank! The Following is example as Design Condition. - Inlet Flowrate of Liquid(Condensate of Steam) : Q [kg/hr] with Density d[kg/m3] With above flowrate, how to decide Tank Size? Above case in under Steady Sate Condition. But, How about NON...