  1. Patel85

    Heat Exchanger Design

    If design code is ASME Sec VIII Div 1, Please refer Appendix-13. Rectangle Box are designed as per this Appendix. Header Box of Air Fin coolers are designed as per this same. TEMA can not be made applicable for this exchanger as Cross Section is not Circular. Regards, VK (Mechanical)
  2. Patel85

    Basic understanding for Fired Heater

    Dear All, Please note that I am Heat Transfer Engineer but till now I have handled only unfired Equipment (Like Shell and Tube Heat Exchanger, PHE, Double Pipe, AFC, etc.) and want to move towards Fired Equipment. I request to help me to understand the basic for fired heater (API 560)...
  3. Patel85

    Flare Tip Turn down from HP to LP

    Dear All, Flare tip is Sonic type and obviously flare is HP flare based on Peak Design Condition. But in Normal Operating condition, Flare will see only 15% Design Load and Very Low Pressure. My Question is whether Sonic Flare tip (designed for allowable DP 4.5 bar) can work with such low...
  4. Patel85

    HP Flare and Flare Header

    Dear All, As I am new for flare package, Please help to understand the basic Concept. 1) What is HP Flare and LP Flare 2) In my case, Datasheet shows allowable Pressure drop across the Flare tip (Sonic Type) and Seal is 4.5 Bar and Flare Header Operating Pressure is 0.1 bar. How it is...
  5. Patel85

    Smokeless Flaring Possible without Air Blower or Steam Supply

    Dear Sir, I have checked datasheet as you have told. As you have rightly said that There are some other Design cases also which has to be considered. One more Question came in My mind. Flare Tip (Sonic) Designed for High Pressure Drop like 4.5 Bar can also work with lower allowable pressure...
  6. Patel85

    Smokeless Flaring Possible without Air Blower or Steam Supply

    Please below the Content Analysis. Regards, VK (Mechanical)
  7. Patel85

    Smokeless Flaring Possible without Air Blower or Steam Supply

    Dear All, Thanks for your reply. Content of flare Gas are as following : H2O, H2S, N2, Methane, ethane, propane, I-Butane, n-Butane, i and n-pentane, n-hexane, n-octane, n-nonane, n-decane, Benzene, p-xylene, COS, Methyl Mercaptan and Ethyl Mercaptan. Molecular weight of Flare gas is 19.97...
  8. Patel85

    Smokeless Flaring Possible without Air Blower or Steam Supply

    Dear All, First of all, I would like to tell you that I am Beginner in Flare Field. So you Might think that the question is stupid. I apologize for the same. but I want to know whether Smokeless Flaring is possible without supplying additional air or Addition Steam. I am handling a project...