Actually initially we also planned for Alloy material but the cost and the welding process is stringent as per construction point of view. So the topic of using CS is initiated. Is it possible to calculated degradation over the period of time or any kind of thumb rule consideration.
A 516 Gr 70 can be used for exhaust system having temperature 450°C at atmospheric pressure. How the note G10 from ASME BPVC
Sec-II D will affect if I select the above material.
Thanks for the comments, My requirement is to make compact drain assembly from the main Header pipe.
We tried 3 piece socket weld valve with prewelded spool of 100 mm to avoid sealing damage due to weld heat. But the complete assembly is goes more than 200mm and its consuming to much place. Have...
Hello,
I want to use forged ball valve for drain and vent application. Valve is of DN15 & DN20, I am planing to to have Male thread connection by that it can directly get assembled on Threaded Half coupling CL3000. I am worried about ease of availability and the orientation of the valve handle...