Hi all,
Have anyone experienced in using Credo and Onyx software for inspection management tool.
Credo: https://credosoft.com/wp/
Onyx: https://onyx-ies.com/partner/production/iq-integrity
Which one would you prefer, and why?
Cheers!
Hi Engineers,
I was searching on remedial actions could be done on in-service passing valve (over passing limit). Is there other options other than replacing the valve?
I could only find standards and codes on valve inspection and testing e.g. API 598, MSS SP-55.
Thank you.
Dear fellow engineers,
So we need to verify anomalies from MFL inspection with UT C-scan on a pipeline.
The model for UT C-scan we used is Olympus Omniscan MX 2. Probe size A12 and scanner speed is 60mm/s.
The range of the MFL anomalies (internal corrosion), approximately a dozen of them are...
Hi Steve & weldstan,
We just realised this when we did PAUT on the weldment at a tee, and yes, the defect is out of acceptance criteria. If it was discovered during fabrication, there was no other way other than re-do the welding again.
The risk is failure of the weldment, and it has been...
Hello engineers,
LOP/LOF was identified on a weldment of a flowline. The flowline has been in operation for few years.
What are the options do we have to mitigate the risk?
Cheers.