  1. nucleareng78

    NFPA 12 interpretation for CO2 supression

    CO2 suppression skids come with a lockout valve on the main CO2 discharge line but not on the pneumatic horn. I understand the pneumatic horn is fed by CO2 to warn those in the enclosure CO2 is present prior to releasing the main isolation valve discharging CO2 (time delayed valve). NFPA 12...
  2. nucleareng78

    Time to heat up lube oil tank

    I think the confusing part is that this skid has a set flow rate and a set heater...can't be changed. So when the oil passes through one time is will not reach the deltaT desired the first time, may take 2-3 loops. But I think I can use a lot of this information posted on here, thanks for the help.
  3. nucleareng78

    Time to heat up lube oil tank

    Understood, but we know how much power we have right now. Wait, I think I'm getting this now, lol. If I know the current power of the heater I can calculate what the delta T will be at the flow rate of the heater circulation line. This in turn can be applied to the total mass of the tank (this...
  4. nucleareng78

    Time to heat up lube oil tank

    can I replace the heat load with the kW rating of the heater in the circulation loop?? Because I need that in the equation somehow...
  5. nucleareng78

    Time to heat up lube oil tank

    If we are wanting to raise the temperature of the tank from X degrees to Y degrees, wouldn't that difference in temperatures be the same for both equations? Our desired delta is the the difference between X and Y, then what is the other delta T represent?
  6. nucleareng78

    Time to heat up lube oil tank

    IRstuff. Your equation cancels delta T and specific heat and just leave total mass over mass flow rate. This may be why I am getting such a low number. Any thoughts?
  7. nucleareng78

    Time to heat up lube oil tank

    After re-working the problem in Mathcad I ended up getting a much lower heating time using IRstuff's method versus my original method...this doesn't quite make sense to me since IRstuff's method is more accurate and takes into account the flow rate of the circulation loop. Or am I just...
  8. nucleareng78

    Time to heat up lube oil tank

    I ended up with 15 hours using the equation above and 9 hours using the original method I posted, so the 15 hours makes more sense since this is a circulation loop. Thanks IRstuff for the input!
  9. nucleareng78

    Time to heat up lube oil tank

    If I know the kW rating of the heater would that factor into the equation above?
  10. nucleareng78

    Time to heat up lube oil tank

    Understood. The inlet and outlet of the circulating loop are 1-2 feet from each other in the top of the tank, but are at different elevations in the tank. Due to mixing in the oil I was trying to stay away from doing an unsteady state calculation since the exact time is not urgent, but rather an...
  11. nucleareng78

    Time to heat up lube oil tank

    Yes I understand, but due to the reasoning behind heating the oil, an exact time is not crucial. Would it be wise to take this time and double it, or even triple it? Just to add some margin
  12. nucleareng78

    Time to heat up lube oil tank

    This is what I did.. Converted 4 kW to BTU/hr. Multiplied this by the specific heat of the oil to get X. Divided X by the total weight of the oil to get Y. Divided Y by the temperature difference I am trying to achieve to get Z. This left me with Z in units of 1/hr Just took the inverse of...
  13. nucleareng78

    Time to heat up lube oil tank

    I'll search around. If I know the specific heat of the oil and the kW rating of the heater, it should be a pretty straight forward equation. Thanks for pointing me in the right direction.
  14. nucleareng78

    Time to heat up lube oil tank

    If I know the kW rating of the heater outside the tank (through which the oil is passing), would this simplify the analysis. I want to treat the tank as a insulated body. An approximation is satisfactory because an exact time to reach a specific temperature is unecessary.
  15. nucleareng78

    Time to heat up lube oil tank

    We are filtering these rectangular lube oil tanks and want to use the skids to heat up the oil during cold startup. I pulled out the old Heat Transfer book but I think I'm over thinking this. If we are taking cold oil out from the bottom of the tank, heating it (specific temp.), and discharging...
  16. nucleareng78

    System curve determination

    Orifice plate increases the pressure in the system correct? From my understanding is that it will push the pump operating point back on the curve (flow goes down, pressure go up). SO I would add the additional head generated in the system to each pipe in the system?
  17. nucleareng78

    System curve determination

    Thanks big inch. There is an existing calc that I should be able to use but it doesn not include the orifice plate at the discharge. This would be on the system curve right?
  18. nucleareng78

    System curve determination

    There is a large diameter vertical pipe with a high flow rate. The flow is going from north to south and we are taking a smaller diameter horizontal line off the side of this pipe. My question: how do I begin to draw a system curve for the inlet of the line we are taking off the large diameter...
  19. nucleareng78

    Centrifugal Pump Bases

    It is fiberglass piping so the nozzle loads will beI minimal. Thanks for the input
  20. nucleareng78

    Centrifugal Pump Bases

    Why do ArtsyBoy and BigInch bother posting then? If you have a problem with a thread it's pretty easy to NOT post in it. This is not a fire pump. It's a pump for a condenser cleaning system. No seismic or safety related requirements. I was simply looking for pump support standards that we...