  1. SystemDesigner

    ESFR AND MULTIPLE ROW RACKS

    All other variables have been satisfied. Is there a limitation with regards to the maximum rack width?
  2. SystemDesigner

    ESFR AND MULTIPLE ROW RACKS

    Good day all With regards to Table 16.2.3.1 of NFPA 13, if one has a ceiling height of 12.2m and a maximum storage height of 7.6m one can apply E.S.F.R sprinkler protection to class 1 to 4 products stored in multiple row racks. Now under the definition of multiple row racks refer 3.9.3.7.3 of...
  3. SystemDesigner

    ESFR - HYDRAULIC DEMAND

    "You do not need to take a full range as you are not required to assume the fire is long and thin." What if the fire occurs along a rack? A rack fire would be thin and long?
  4. SystemDesigner

    ESFR - HYDRAULIC DEMAND

    Thanks for the replies guys. There is some politics behind this design and i've been asked to stick to a tree system. Just out of curiousity, what were the range sizes on a grid system that was done by anyone?
  5. SystemDesigner

    ESFR - HYDRAULIC DEMAND

    No. I'm using a hydraulic program to size the pipes. Why do you ask?
  6. SystemDesigner

    ESFR - HYDRAULIC DEMAND

    Thanks for all the replies guys. the reason i ask is because i have a riser on the main. Will the riser have to be sized to accomodate all 8 sprinklers or only four sprinklers per branchline. the riser will obviously be bigger if i have the take all 8 into operation as it needs to handle a...
  7. SystemDesigner

    ESFR - HYDRAULIC DEMAND

    would x1,2,3,4,9,10,11,12,17,18,19,20 be correct? would i not have to take a full range? e.g 1,2,3,4,5,6,7,8,9,10,11,12? I'm confused
  8. SystemDesigner

    ESFR - HYDRAULIC DEMAND

    Hi guys I have a query regarding how to take the number of sprinklers in operation. The rules state: 15.4.3 The design area shall consist of the most hydraulically demanding area of 12 sprinklers, consisting of four sprinklers on each of three branch lines. If this is my arrangement...
  9. SystemDesigner

    Tank in fill valve and flow device

    Hi Guys I need some assistance.... What type of valve should i use for the tank infill? Should the tank infill line have a flow measuring device to monitor the rate of infill. The above must be in accordance with NFPA std.
  10. SystemDesigner

    Maximum water velocity (NFPA13)

    Hi Guys & Gals What is the maximum permissible water velocity in sprinkler pipes?
  11. SystemDesigner

    Rack protection

    "This is not the place to ask big multi variable questions" I thought this forum was here to assist people I guess NOT!
  12. SystemDesigner

    Rack protection

    Anyone know how i should expedite this?
  13. SystemDesigner

    Rack protection

    Hi guys some additional info.... Roof Sheeting Heights: Low Bay is at 8.6m at lowest point and 9.7 at highest point. High Bay (Monitor Bay) is at 10.2m at lowest point and at highest point is at 12.0m System Type: Wet Pipe System. Roof Type & Slope: Corrugated Sheeting and roof angle is 3°...
  14. SystemDesigner

    Rack protection

    Hi guys I'm new to this forum and require help in designing a system for the below mentioned: Goods stored in racks in a coco cola factory Plastic bottles, drums and boxes containing syrup/raw material. the above needs to be in accordance with NFPA. All tips welcome. Thanks
  15. SystemDesigner

    Handheld Laser Measuring Device

    Hi guys I'm new here. I currently use the Hilti PD40, great device no problems so far.