Good day to all.
Boiler operating at 34 bars, 370 C.
MAWP is 40 bars.
One Safety valve (SV 1) installed at superheater.
Two safety valves (SV 2 and SV 3) installed
at steam drum.
Question: At what specific pressure should
the three valves pop-off?
Small boiler will supply only steam to process dept.
at Pressure reducing and desuperheating station one, 3 kg/cm2 180 C, the total steam flow req is 23 TPH.
at pressure reducing and desuperheating station two, 6 kg/cm2 350 C, the total steam flow req is 5 tph.
So what will be the small...
hello good day. Currently, our power boiler is operating at 33 bars, 370C superheated steam, steam flow at 32 ton per hour. supplying steam to steam turbo-generator, extraction type.
I want to purchase a packaged type boiler to serve as back-up in case the big boiler will be subjected for...
good day,
can anyone give me the formula for pendant Superheater heating surface area?
Boiler Specs: two drum, water tube, biomass fired, reciprocating grate..