  1. dewins

    Compaction test for backfilling works using sand

    Is there an ASTM standard referring on this? EPC contractor preferred to use sand saying there is no standard test and visual inspection is enough. Sometimes, soil will be mixed with sand as binder and will not conduct FDT either. There is something wrong I think. Please enlighten us.
  2. dewins

    Vertical rebar of CMU

    guys, please refer on the attached drawing. thanks.http://files.engineering.com/getfile.aspx?folder=7d9633d3-3a42-4a72-a6e7-6725ee2c62a2&file=Screenshot_2013-12-11_12.16.33.png
  3. dewins

    Vertical rebar of CMU

    Can somebody remember the ACI code stating that vertical reinforcement shall be anchored to roof beams or structural beams. We would like to know because the EPC contractor just wanted it to have angular plate and anchored with drive pin. Thanks for the help.
  4. dewins

    ASTM 2729 for sanitary drains

    IPC Table 1102.5 mentioned the use of PVC pipes as per ASTM 2729 for subsoil drains. Can we use the same for sanitary drains like for water closet?
  5. dewins

    Verification of allowable soil bearing capacity

    TLHS, the EPC contractor based their allowable bearing capacity (design criteria) from the conducted soil investigation during planning stage. Is there a code reference to require them to perform foundation load test?
  6. dewins

    Verification of allowable soil bearing capacity

    Soil bearing capacity (say 200KPa) is always stated on design criteria, specification and drawings. Do we need to verify for each foundation, if not, what is standard reference for this? We normally perform PBT for foundation of buildings. What test is applicable for series of isolated...
  7. dewins

    6ft thick foundation

    guys, do you know of some vertical construction joint detail that can be applied for this 6ft thick mass concrete?
  8. dewins

    6ft thick foundation

    appreciate the thoughts, slideruleera. more power!
  9. dewins

    6ft thick foundation

    thanks, hokie. we are looking for sound engineering practices for this. any suggestions for possible alternative or reference that can be applied for construction jointing detail?
  10. dewins

    6ft thick foundation

    is there a code violation if concrete casting will be done with vertical construction joint? is it structurally sound not to pour monolithically? also, what are the measures to apply in achieving quality concrete and if permitted, construction joints?