  1. atrizzy

    Concrete column pour stop

    BA, this is why I always specify the column pour stop to be 1" below underside of slab.
  2. atrizzy

    Talk me down, please

    I just want to take a moment to thank everybody who contributed to this thread. There is a LOT of food for thought here and this will surely impact our approach to the wording in the report and the information we provide. If anything interesting comes of this, I'll be sure to update the...
  3. atrizzy

    Talk me down, please

    BFstr, I'd rather not share any pictures as to limit chance of identification. The building is a slapped together old mining mill way out in the middle of nowhere. Minimal seismic, but decent snow loads.
  4. atrizzy

    Talk me down, please

    LittleInch, rest assured I'm thankful for all of these responses.
  5. atrizzy

    Minimum steel reinforcing for grade beams

    I'm not as familiar with ACI as I am with CSA, but if the member is meant to act like a 'beam' (horizontally oriented flexural member spanning between supports) I believe it should be detailed as one.
  6. atrizzy

    Talk me down, please

    I think external bracing is probably the way to go. One side is inaccessible so it'll have to be rigid, but a small price to pay, and one the demo contractor will be thankful to hear of in advance anyway.
  7. atrizzy

    Talk me down, please

    I have no doubt that this is how it's working, but it was certainly not meant to by design. I can see the ends of the bracing that was cut. In one location they left half of it lying against the equipment they installed. In another, you can see from when the building was built a note written...
  8. atrizzy

    Talk me down, please

    That's a good idea.
  9. atrizzy

    Talk me down, please

    Thanks Dave, except I've been asked to certify the building as safe to enter from a structural perspective...
  10. atrizzy

    Talk me down, please

    So I'm tasked with assessing if a crew of workers can enter a building safely. It's an old industrial PEMB type building (moment frames in one direction, bracing in the other, wind resisting gable ends) and in pretty bad shape, but has stood in place in its current state for probably 25 years...
  11. atrizzy

    NBCC 2020 Climatic Data

    EngDM, my comment was more to point out that the fee is small with respect to what it could mean for your designs, especially if you're dealing with a remote site. I do remote site designs all the time and have them on speed dial. I suspect there's more to it than the seismic calculator. I...
  12. atrizzy

    NBCC 2020 Climatic Data

    Just call Env Can. It's 200 bucks and you have something to hang your hat on. A little difference in elevation can make a huge difference in snow load, to name just one example.
  13. atrizzy

    Half CMU half wood wall

    You'd have to design the footing and CMU wall as a cantilevered retaining wall, and you're good to go.
  14. atrizzy

    What type of load is applied to a beam that accepts a hung beam off of it?

    It is a point load, yes, in an idealized scenario. However, as you sound like you realize, there are a few hoops to jump through to convince yourself that it's an idealized point load at the top of the beam. Firstly, the vertical load has to make it through to the beam, which the hanger...
  15. atrizzy

    Structural details for standard shipping containers

    Does anyone have a resource identifying the structural detailing of a standard 40' shipping container (or, 'seacan' if you're in the know)?
  16. atrizzy

    Log wall building.

    Try checking compression perpendicular to grain.
  17. atrizzy

    Checking foundation for shear force

    When significant movement is intolerable, I typically use friction and at-rest pressure (using Ko instead of Kp).
  18. atrizzy

    CMU Wall Opening with W Shape Lintel

    Why not add stiffeners to the web until you're comfortable that the flanges won't fail? Then it's a matter of resolving the torsion at the end of the lintel, perhaps with an HSS post?