Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Cassidy G

    API 650 Closed Tanks

    Sir IFRs, ok sir I will look for 13th edition. But for now I will use the 12th edition. Thank you.
  2. Cassidy G

    API 650 Closed Tanks

    Sir HTURKAK I have sample of tank design. The designer used API 650 11th edition (Section 5.1.5.9 and Annex F Fig. F-2. The minimum participating area at roof to shell junction used by the designer is A = [D^2/(0.432sinθ)](T/2.2) At 12th edition A = pD^2/8Fatanθ I'm using 12th edition. But...
  3. Cassidy G

    API 650 Closed Tanks

    Sir LittleInch, My company is for indusrial. Before my company has designers for large tanks. For now, they only have me with 1 year experience. I'm interested with this therefore I giving my best to design it. No other engineer can help me here in my company.
  4. Cassidy G

    API 650 Closed Tanks

    Sir HTURKAK Yes, it is fixed roof. For top curb angle, can I use double angle and form it like a channel? Or can I use Channel diectly. Because minimum required participating area is larger than the area provide by shell, roof plate, and angle. Thank you.
  5. Cassidy G

    API 650 Closed Tanks

    Good day, Engineers. I'm designing Closed Storage Tanks using API 650 - 12th Edition. Can anyone clarify the difference between top angle and top wind girder? Because in my understanding. For Closed Tanks, top angle must be use. The top wind girder is only for Open Tanks. Therefore, I'm not...
  6. Cassidy G

    Wooden stairs with handrail dead load

    jimstructures National Structural Code of the Philippines. At ASCE and IBC, stairs tread and landing live load is 100psf. Is this for public assembly building or it is also for residential house?
  7. Cassidy G

    Wooden stairs with handrail dead load

    Engr jimstructures and hotmail box. I used NSCP 2015, our code has no live load for stairs. Some designers here only used live load of occupancy which they are associated. Yes I check the ASCE and IBC before. ASCE/SEI 7 (ASCE 2016) has dead load for stairs. IBC live load Handrail 50lb/ft...
  8. Cassidy G

    Wooden stairs with handrail dead load

    Engr hotmailbox. By the way, do you have reference code or book for the 40psf dead load and 100psf live load. Thank you.
  9. Cassidy G

    Wooden stairs with handrail dead load

    Nope, Sir hotmailbox, he is the draftsman and feeling architect. I'm the engineer here and don't have the power to tell the size if treads. That is true. Because of ego. I'm 27yrs old and he is 58yrs old. But no age for professional. That's why I laugh hard hahaha. He acts like a boss hahaha.
  10. Cassidy G

    Wooden stairs with handrail dead load

    You're right Engineers. This is a very easy calculation. But knowing only the density of the wood and not the sections, sizes of treads, handrail, etc. is very hard to imagine. Thank you.
  11. Cassidy G

    Wooden stairs with handrail dead load

    Hi, Sir hotmailbox and Sir jimstructures. I only have floor plan and the stairs has no details, no section views, no sizes, etc. Like I have said, I tried to ask the draftsman, he said "it is only a wooden stairs don't mind it. Design the concrete frame only." Last time I ask him what kind of...
  12. Cassidy G

    Wooden stairs with handrail dead load

    Good day, Engr. Agent666. Yes, I have the computed weight already base on my judgement. I just want a second opinion or any advice. Thank you.
  13. Cassidy G

    Wooden stairs with handrail dead load

    Good day, Engineers. I'm design a 2 storey residential house. It has wooden stairs. Only a Draftsman draw the architectural plan and not an Architect. I ask the draftman what kind of wooden stairs it is, for me to know or search the weight of it. He replied, (Don't think about the weight of...
  14. Cassidy G

    RESIDENTIAL BALCONY RAILING WEIGHT

    Hi, Engr. I didn't see the weight of those materials. Thank you by the way.
  15. Cassidy G

    RESIDENTIAL BALCONY RAILING WEIGHT

    Hi, Good day Engineers. Is there anyone have standard weight of residential balcony stainless steel railings. Or you can give some link. Thank you.
  16. Cassidy G

    Wall Load into Floor Load

    No, Sir. This concrete structure. Yes, Sir. Forget about foundation. I know how to design it. I'm just asking how can I apply the wall loads to beam. The wall is partition and located at the center of slab without intermediate beam.
  17. Cassidy G

    Wall Load into Floor Load

    This is suspended slab
  18. Cassidy G

    Wall Load into Floor Load

    Concrete two storey residential housse. Psf or psi, I mean. I will check if intermediate beam is necessary.
  19. Cassidy G

    Wall Load into Floor Load

    Hi! Good day, Engineers. Can anyone help me how to convert wall load into floor load. Can you give me formula or can anyone explain it. Let say, Pw is the weight of masonry wall given by the code in kPa or psf, psi. I'm going to check if the slab can carry the masonry interior wall/partition...
  20. Cassidy G

    OSHA Handrail (top rail) 200lb exac

    jimstructures Yes, wrong spelling. Thank you.

Part and Inventory Search