    Gate Valves in HF Acid Service

    I don't know the size of your gate valves, but for smaller ones, using a Kammpro gasket (with a Monel core) might not be suitable for the seal between the bonnet and the body of very small valves. However, using a welded bonnet design can significantly improve the sealing performance in...
  2. acdxxx177

    Cryogenic Valves

    You can refer to the following standards: MSS SP-134 Valves for Cryogenic Service Including Requirements for Body/Bonnet Extensions Specifies requirements for extended bonnet lengths. Outlines measures to prevent abnormal pressure build-up. Specifies testing procedures including...