For an unconfined aquifer , we have this pde for the water table position , of course after making the Boussinesq somehow linear :
∂²(h²)∕∂x² + ∂²(h²)∕∂y² = (2s/k ) ∂h/∂t - 2N/k
N and K and S are constants .
would u tell me what type mathematically it is ? this equation , in respect to h^2...
How about editing and importing from Excel ?!
maybe im confusing Etabs with Sap...cause i learned Sap mostly and been told Etabs is the simple one ....
anyhow...i liked the way i could bring anything from Excel into SAP especially for long lasting entries :)
I have a problem with Show Table command in Etabs 2015 , it is not like older versions for me... i mean i cant find the option for show table....like we could choose load combos and selection only and ....
where is it in Etabs 2015 ?
help me out guys ~
first , thanks for your attention ! and time !
umm , as the specifications tell me , in the NS direction my lateral bearing system is moment frame , yeah , but that is not the case for the EW directiom , i assumed that bracing system will act on that direction only , and frame is simple ...
yeah , i am doing hand cal instead of letting Etabs ... , i like to understand things , i really have no experience ,
okay , i will attach the actual plan here :
http://files.engineering.com/getfile.aspx?folder=2bdfc061-b7e8-4b56-bb46-1948ba98fb61&file=Untitled.jpg
jayrod12@ thanks , i neglected it so far , but it produces a great deal of eccentricity , and torsion , as u said ,
KootK@ i dont get you , by fictional frames ,, i mean , i only need to calculate in NS direction , and in that direction under E and F we have only one column , do u mean i add...
OKey-doke , and yeah , this question is well defined under seismology , i dont know why ....
here is the pic :
http://files.engineering.com/getfile.aspx?folder=afce5ffd-5e11-4695-9125-9feeb14cc4ce&file=asa.png
I have posted same problem in Seismology department here , but i think i explained in a not clear way , i got no reply ,,
well , the problem is , i am calculating lateral stiffness for frames , steel frames , and to reach story lateral stiffness and CR point .
problem is , i have an oblique...
For calculating the center of rigidity of a floor system , i know that i have to first find the rigidity of frames in horizontal and vertical direction ,
but now i am confronted with something that im not capable to understand and calculate ,
i will attach the columns plan here in this post ...
Thank you , for your guide and help .
i really needed to know if surplus calculations are wrong are just to be more accurate , i was in doubt , ,
and by surplus i meant walls ))
okey-doke !
you know , when i talk with friends , they just tell me that , forget about walls , and this half height difference in first floor , they can be neglected , no big difference in CM happens ,
... but i dont like to neglect ,
and about these partitions , why is that they say use uniform load ...
I know it seems very elementary , but i have problem and doubts ,
well i want to know , when im going to calculate center of mass in each floor , without any software , should i calculate the weight of walls ? walls at perimeter and partitions ?
and what about that half of the height of walls...
Hey guys ,
i need some resources and information about shell structures ,
i wanna know how they make it really , which material they use , how they erect those type of structures , ...
where do u suggest i look it up for ..?
is it any special guide or point for positioning the columns in a plan ?
i mean , when i get the plan from an architect , after it , i have to place the columns in the very first place ,
any guide for doing it the best way ?
is there any best way or it is based on engineering experiences ?!
could anyone help me with the definition of the center of the resistance in a building or anywhere )
and the difference between this and center of stiffness , im really in need of knowing it ,
tnx for your help )
I was calculating lateral earth pressure at rest for a submerged or actually partially submerged soil.
with a surcharge q for instance.
and i dont understand why this surcharge does not add to pore water pressure , and we only add it to effective stress.
is it the same when water table is at...