Fox Thermal's model FT1, apparently it can go higher than 100:1. I was looking at 20,000 SFPM standard feet per minute in a 3 inch schedule 40 pipe. It can also switch between gases like the FT4A we have.
georgeverghese,
I think you are correct from what I have read up on the vortex meters.
danw2,
Thank you for elaborating on why the vortex meter is probably not suitable. I found a less expensive model of the one we originally purchased from the same company so I think I'm good for my gas flow...
Hi Little,
20,000 SPM or 1050 SCFM equivalent for our pipe size, I worked out the specs with the company I bought from before that information is listed here- https://www.foxthermal.com/configure/?AppID=25497
What we have works well, but this is a research facility and I'm looking for a more...
We are measuring using a thermal mass flow meter right now and it works great, but I am looking for something under $5K. The application is 20,000 SFPM in a 3" sched 40 pipe