  1. ngs

    20 year old detroit diesel engine

    I am working on creating a remote wireless throttle control for a 20 year old detroit diesel engine. I would like to know if anyone knows how the battery, starter, solenoid, and alternator are wired to an ammeter, DC contacts and a start button. thanks ahead of time.
  2. ngs

    splicing different size conductor

    thanks you have answered my question. ngs
  3. ngs

    splicing different size conductor

    I have an existing #6 AWG feed cable coming off a distribution panel which extends 520 ft. to the load. I would like to take this feed conductors off the panel and connect to a dedicated MCC. Cost is an issue, so I want to know if I can splice this cable with another cable? The 520 ft feed...
  4. ngs

    UNIT 3 EXCITATION FIELD FLASHING PROBLEM ANALYSIS

    Anyone, I am trying to understand what the problem is and how to resolve the issue. I have copied notes on the above subject. Can someone explain. From C. T. Sent Tue 3/21/2006 1:31 PM Subject: RE: FOLLOW UP: UNIT 3 EXCITATION FIELD FLASHING PROBLEM ANALYSIS R. J. H., YES, I AGREE IF WE...
  5. ngs

    4160V motor RTD monitoring

    Anyone Looking for suggestions on how I can setup monitoring equipment to monitor continuous temperature for a 4160V motor via 10 ohm RTD. Currently, I am looking at terminating the RTD leads to a signal conditioner, 24VDC power supply, and an 8 channel voltage logger. OMEGA part#: OM-CPOCTVOLT
  6. ngs

    Allis Chalmers 4160V motor, 3000 hp

    Anyone We have a 4160V, 3000 hp circulation water pump motor where the stator coils show cracked VIP resin at the spacers and this is typical all the way around on the ODE with little on the DE. I am curious to know if I should be concerned about this. Does anyone know what could be the cause...
  7. ngs

    Transformer sizing for a motor starter

    Can anyone point me in the right direction, to correctly size a transformer for a 3 phase motor starter? I am interested in calculating the correct power rating in KVA. I am not sure if this is correct, but I am using this formula: KW = HP * 746 / 1000 KVA = KW * 1.5(Form Factor)
  8. ngs

    Integrating Foxboro data highway and ethernet

    This is new to me so I would like to ask for some assistance on how to integrate a (Foxboro IA) data highway and ethernet. The ethernet will be used to send alarms from the transforer to the control room, using Allen Bradley PLC. So far this is what I have. Currently a (Foxboro IA) is used...
  9. ngs

    Transformer dielectric coolant fluid

    Appreciate all of your inputs. I learned am learning quite a bit. Busbar, good question, I'll definitely look into it. jghrist, In this case, our transformers are using mineral oil. Thanks to all
  10. ngs

    Transformer dielectric coolant fluid

    Busbar, I did contact the manufacturer and they claim to have the best transformer oil to be used as a retro-fill on existing transformers. Cooper also claims that there are current users of this FR3 which are several utility companies. So, I emailed five of the utility companies, asking if...
  11. ngs

    Transformer dielectric coolant fluid

    I would like to ask if anyone has used the product, Envirotemp FR3 Fluid manufactured by Cooper Power System to retro-fill an existing distribution transformer(7500 KVA)? If so, would you recommend it? Thanks, ahead of time. ngs