Continue to Site

Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: MHRG
  • Order by date
  1. MHRG

    Process Engineering Design to Advanced Process control (APC)

    Please help me for the right choice of carrier growth, the following points need to be clarified . 1.What is the scope of a process Engineer in Advanced Process Control (APC) 2.Is it a good option to shift your job from Process design to Advanced Process control (APC) if you have a little bit...
  2. MHRG

    L/D Ratio of storage tank

    I didn't mean to remind anything MJCronin. Apologize if you felt anything bad from me. All the responses were 100% useful.
  3. MHRG

    L/D Ratio of storage tank

    Thank you Every one, all response where informative. I realise that, In main case "bimr" is on the money . "Economical Tank fabrication", ie. all other tanks are site fabricated while these tanks are shop fabricated which makes the deference.
  4. MHRG

    Flare adequacy check and modification

    In my case the ratio is well above 5%. Existing flare capacity is 35 MMSCFD and the the rated flow of new PSV is 24MMSCFD (governing case: Tube rupture)
  5. MHRG

    Flare adequacy check and modification

    Thank you George for your suggestions. Is there any possibility to get the spread sheet you are mentioning.
  6. MHRG

    Flare adequacy check and modification

    Thank you Emmanuel, Peak flow case of each Relief system connected to flare is taken as the governing case for Flare sizing. In the second point, Is it evident from any standards, to convince the client ?
  7. MHRG

    Flare adequacy check and modification

    My requirement is to add a PSV discharge to an existing flare system. My plan is to model the entire existing flare system and then check for the adequacy of the new one. What is the best way to model the same, is it by Modeling using Flare net or using Hysis dynamics environment.
  8. MHRG

    L/D Ratio of storage tank

    What is the significance of Choosing optimum L/D Ratio in Atmospheric storage tanks.? As a normal practice the L/D ratio of atmospheric storage tank is considered within the limit of 0.5 to 1.1. However, it is noticed that for some tanks it doesn't follow this limit. For example, fresh Amine...

Part and Inventory Search