Hello Everyone!!.
i'm calculating a orifice plate, not for measure, only for restrict the flow rate.. The customer say me that he need it acording to aga 3 and ASME B16.5.
Ok.. I'm calculating it with aga3 software, the values give it are OK.
Now, i have the beta radio and the others values.
But...
Hi michael, i can try explain with my bad english
if my instrument calibration range for level only -32.6 mabr to - 10.7 mbar.
HERE YOUR SPAM IS 21,9 mBAR.
I choose DP transmitter A, instrument range -1000 to 1000 mbar and span are 5 to 1000 mbar.
Your max spam es 2000 mBar or 2bar.. From...
You can download Krovasel software from the Krohne site, it's only for krohne products but you can have any idea about the range, density and max flow rate.
Note...The spam ratio on the rotameters is only 10:1.. Please note it... Whats is your aplication?.
Best regards.
Mj see below.
Zicor in spanish. zecor in english.
Is a SS with a low charge of silice.
Best regards.http://www.mecsglobal.co.za/content/SulAcid/zecor.asp
is too simple.. Wich flowmeter you can use? or which fluid like to measure??.
example.. For a electromagnetic flowmeter you need 3 m/s (fluid velocity) at the max flow.
you can use ONLY ZICOR for pipes.
Zicor is expensive but is too resistant to the corrosion.
maybe you can use PVRF too.
If money isn't a problem, i prefer use a zicor pipe with a second container in 316SS with a preassure swicht for leak deteccion like the mass flowmeters. This is the...
you can use a GPRS flowmeter. The type thats you need is a electromagnetic flowmeter.
I known and use a ABB flowmastes and krohne metering.
Both use a small electronics with batery and GPRS chip.
Best regards.