    Lean amine loading for MEA

    I was assuming that temperature was really a factor in production of heat stable salts but our tem in the contactor is abour 120 to 140F. BUT the amouth of Oxygen in the inlet gas is about 1000 ppm average , in some cases more. Can be O2 in the gas a source of corrosion in the contator, more...
  2. herrera01

    Lean amine loading for MEA

    Thanks dcasto: I have severe corrosion in the contactor and the heat exchanger of the lean amine does not have good control. My problem is that i do not know what would be the temperature that the contactor should have in order to have less formation of HSS and Bicine. The lean amine temp...
  3. herrera01

    Lean amine loading for MEA

    Dear Experts: Can you please confirm what is temperature and pressure that reduces the formation of heat stable salt and bicine in a Co2 removal contactor...?