Search results for query: *

  1. Sempronio1960

    Operation of asynchronous engine in escalators moving down

    @Skogsgurra Ok, my question is: if |T|>|T|Run away poin, is the motor accelerating, also if is it in generating mode? @itsmoked Motor not engine.... Of course :-)
  2. Sempronio1960

    Operation of asynchronous engine in escalators moving down

    I am interesting about operation of asynchronous engine in escalators moving down. Is the engine working as generator? If so, can an overload beyond maximum couple cause an escalator overspeed? Moreover, in generator operation, is the energy lead into grid or dissipated in a rhesostat? Thank for...
  3. Sempronio1960

    Insulation provisional airline 11 kV

    A three-phase 11 kV aerial line on metal supports must be transferred to the new higher metal supports substantially in line with earlier. The supply line must be kept available, although of course out of service, during the raising of the new poles, but one of the phases goes to touch them. It...
  4. Sempronio1960

    Electrostatic charges on a bare wire stretched in the air?

    Thank all for your answers. Greetings with this link: http://mappingignorance.org/2013/05/09/on-bees-antennae-and-electrical-flower-power/
  5. Sempronio1960

    Electrostatic charges on a bare wire stretched in the air?

    >electricpete ... how does a cloud get charged ... The clouds get charged by friction between particles due to convective movements. I don't think clouds are comparable to conducting bodies. However I will ask more information about environmental conditions. > waross ... Do you think that it...
  6. Sempronio1960

    Electrostatic charges on a bare wire stretched in the air?

    >marks1080 ... acting like a capacitor ... >jghrist ... the beam got charged with static electricity ... I have some difficulty imagining the physical phenomenon. The beam suspended and that placed on the ground are both conductors (not dielectric as rubber etc.) and not connected to emf, so...
  7. Sempronio1960

    Electrostatic charges on a bare wire stretched in the air?

    >waross ... When an un-energized line is in proximity with an energized line a potential may be induced. ... In these cases would be the induction magnetic, not electric. Right? >waross ... Multiple grounds may result in a circulating current of several amps or more. ... In these cases it is...
  8. Sempronio1960

    Electrostatic charges on a bare wire stretched in the air?

    >Marmite (Electrical) ... line runs in parallel with other lines ... There aren't any lines nearby. There was an arc between a metal beam, suspended by a crane under a line in construction never fed, and another beam placed on the ground. The conductors of the line under construction had been...
  9. Sempronio1960

    Electrostatic charges on a bare wire stretched in the air?

    A bare wire stretched in the air, in particular the conductor of a power line taut between their supports on its isolators, and never fed, without any type of electrical connections at the ends, can be the site of electrostatic charges? If so, why?
  10. Sempronio1960

    MV cables with LV cables

    Thank you for answer. The Italian rules do not preclude the laying of cables MV cables together with LV cables.
  11. Sempronio1960

    MV cables with LV cables

    I would like to ask if it is allowed lay MV cables (e.g. 20 kV) in tunnels or wells where LV power/control/monitoring cables are laid. See photos, please. http://snag.gy/p1DsC.jpg http://snag.gy/wswzq.jpg http://snag.gy/Jb5o7.jpg http://snag.gy/1iGwA.jpg
  12. Sempronio1960

    Suggestion for a refresh-book about power plants

    >Are you looking for a book about design, calculations, Design and calcultions: Nasar (Schaum) would be fine if there were too many errors.
  13. Sempronio1960

    Suggestion for a refresh-book about power plants

    I am looking for a refresh book about power plants/systems. I like Nasar "Schaum's Outline of Electrical Power Systems" but I find many mistakes. Do you have any suggestion? What do you tihink about Wayne "handbok of electric power calculations"?
  14. Sempronio1960

    Anti-theft solutions for copper cables: questions

    Yhans to all for your suggestions. My problems doesn't concern copperweld but insulated cables in cable trenchs, as in http://bernatom.com/uk_savoir-faire-recouvrement-cables-cuivre.php: the currents are little.
  15. Sempronio1960

    Anti-theft solutions for copper cables: questions

    Do you know these http://bernatom.com/uk_savoir-faire-recouvrement-cables-cuivre.php http://bazkideblog.eraikune.com/2012/05/sistema-antirrobo-de-cables-de-cobre/ ? Any experiences? I like the first. Do you have other suggestions?
  16. Sempronio1960

    Concrete platforms in a substation

    @7anoter4 Do you have any suggestion for good design (links, documents, codes, examples in the net)?
  17. Sempronio1960

    Concrete platforms in a substation

    Concrete platforms with electrowelded net are being realized in a substation renovation, see the photos. Do you share this solution?. I have some doubts about those because the earth grid becomes inaccessible.
  18. Sempronio1960

    SF6 "Voltage Transformers" in HV (150 kV) lines

    Do you have experience of SF6 "Voltage Transformers" in HV (150 kV) lines? Which problems would you consider (explosions, ecc.)? P.S. example http://www.trenchgroup.com/en/Products-Solutions/Instrument-Transformers/Inductive-Voltage-Transformers/SF6-insulated-Inductive-Voltage-Transformers
  19. Sempronio1960

    How to use a total station?

    >This is not a repair shop. You should probably talk directly to a Trimble service engineer. This is really a good idea! Thank you very much!
  20. Sempronio1960

    How to use a total station?

    >What exactly is your question? Excuse for my poor English. "My" Total Station is a TRimble 5600, DR200+. I cannot measure with it distances greather than 6-7 m. The instrument has not been used for two years. It ma be depend from backup battery?