Shear strength of the bulk resin is quoted by resin manufacturers or calculate form G=E/2(1+v). Doesn't have a lot of practical use though. If after shear strength of a fibreglass laminated joint a figure of 7 MPa (100psi) glue bond area layup strength is used in many codes etc for CSM, with a...