we already use some pipe diameters before and after the RO (restriction orifice).
the multistage device is used because we need to decrease pressure from 40 to 5 bar. this kind of devices are used to gradually decrease pressure
Hi! Thanks for your answer. This is what I tried at the first step, but I had to compare that results with other ones calculated as a multistage assembly and they didn't really match...
Does anybody know how to calculate a multistage restriction orifice device?
thread124-150149
Hi all,
I've been reading that thread about Restriction Orifices and I still have some doubts.
In our case, we must design a multistage device, wich includes 3 restriction orifices in series. Is there any difference between multistage and simple restriction orifice...