  1. biomech

    Pressure sensors to measure force for walking

    Try this company. http://www.tekscan.com/medical.html GL
  2. biomech

    Kevlar composites

    Thanks PEmrich for your reply. I looks like we are applying about 600 N of clamping force onto the surface of the carbon composite through the 2.0-mm wire. Thanks
  3. biomech

    ASTM F 382

    This standard is for the static bending properties of metallic bone plates. My question is how the equation for Bending stiffness was derived. The equation they give is the following: Bending Stiffness = (5/324)*B^3 * Bending rigidity Where: B = distance between roller supports and Bending...
  4. biomech

    Kevlar composites

    We are trying to make a composite surface that we can clamp a 2.0-mm wire onto that will be required to carry a transverse load. We are having problems making the surface of our composite hard enough to prohibit the wire from sinking into the surface when we clamp down on it. Does anyone know if...