    Substitute for vegetable fiber gasket

    I have an control oil system. Normal pressure is 150 psig and 200degrees F. Oil is used for controlling valves on a Turbine. The oil is always found on the floor (10-15gal over 3 months). Need to find a substitute for vegetable fiber gasket. Anybody has any suggestion. THanks
  2. bopsyseng

    increasing Vibrations

    The spoolpiece is a rigid steel piece but it is bolted to the coupling. The process fluid through the pump is around 350-400'F. Eventhough the room has a air cooler, just above the pump where the coupling and the spoolpiece is situated (inside a 10ft canister) does get heated up not upto 300'F...
  3. bopsyseng

    increasing Vibrations

    Electricpete has a good suggesation. However, here is what we did. We found the spool piece (extension between motor and pump coupling) was out of alignment (20 thou or 0.020). The out of alignment was due to bolts that were used to connect the spool piece. This caused the spool piece to shift...
  4. bopsyseng

    increasing Vibrations

    The coupling is not grease packed. In order to make sure the isulating plate is not coming loose we ran uncoupled and found the vibs are steady and in the range of 0.04-0.045ips. Also the coupling is not grease packed.
  5. bopsyseng

    increasing Vibrations

    The vibration is at running speed. Vertical motor. Vibs are high in A2 direction, no axial shift, temperature of the fluid is 350'F. No change in temp. The pump is underground. Motor is mounted on a can 5-10ft over the pump. If you think it is thermal bow is there any other way to verify this...
  6. bopsyseng

    increasing Vibrations

    We recently refurbished a 1750hp motor as part of Preventative Maintenance. After the installation of motor the vibs increased from 0.2ips to 0.63ips over 7 hour period. The problem was assiciated with the insulation plate. After fixing the insulation plate the uncoupled motor vibs were 0.065ips...
  7. bopsyseng

    Oil level in the vertical motor lower bearing

    We have not noticed any foaming. The standstill oil level mark will 1/2 submerge the bearing. The operating level is not suppose to change much however, we are noticing 1/2" increase.
  8. bopsyseng

    Oil level in the vertical motor lower bearing

    I have large (1750 hp)vertical AC motor on a pump. The oil gauge has standstill level and operating level bands. Before starting the motor the oil level was at the middle of standstill level however, after starting the motor the oil is 1/2" higher than top of the operating level band. No leaks...
  9. bopsyseng

    Need vibration limits on large AC vertical motors

    The vibration analysis shows only one variable sine curve. We assume it may be due to imbalance. The bearings appear to be in good shape (based on sine curve). We did recommend 0.7ips as cut off vibs to remove pump from service. The vibs at present are stable at 0.5ips. We will try to balance in...
  10. bopsyseng

    Need vibration limits on large AC vertical motors

    Motor was balanced before installation. One time motor tripped due to ground fault, second time it tripped due to blackout (08/14/2003). Motor also has a Mechanical Seal.
  11. bopsyseng

    Need vibration limits on large AC vertical motors

    I have a large AC motor (1750HP, 1800 rpm) installed vertically. every time it trips the vibs goes up by 0.1ips Started with 0.3ips after two trips 0.5ips. how long can I continue before s/d the motor and get it balanced.