In MSC.MARC 2005r3 and MSC.MARC 2007r1 you do not need a user subroutine to grow or scale a rigid surface. On the CONTACT definition you can specify GROWTH FACTOR FOR RIGID SURFACE in each cartesian coordinate direction. The Factor can have a table associated with them to make them change with...