  1. jasonf987

    Cost of operating AC vs. DC

    From a maintenace point of view an AC installation is far cheaper, especially if you have a failure of some sort.
  2. jasonf987

    Mini Hydro Scheme

    Thank you all for your input, it def does give one quite a bit to think about. I will try and put some answers to the questions posed. I agree, my calcs put me in the region of roughly 200kW aswell, the installation would be on our company premises and due to the fact that we already have...
  3. jasonf987

    Mini Hydro Scheme

    yes, i am looking at an induction motor. I actually want to see if i can't use a pump as a turbine and then couple up the motor to run as a generator. This is on a system where we have effluent running away from our mill. It drops a total of roughly 60 meters and has a flow rate of in the region...
  4. jasonf987

    Mini Hydro Scheme

    Is there any limitation in the size motor which can be used as a generator other than physical size? I understand that by driving a motor above synchronous speed it will start acting as a generator, providing it has a magnetic field set up via some reactive energy, but can you use this approach...
  5. jasonf987

    Broke and in need of an education

    if costs are the major problem, look at a couple of places around the world which have been accredited to the "Washington Accord" and see if their costs are comparible to what you are currently paying. Just don't underestimate the importance of a quality degree as this is going to be your...
  6. jasonf987

    Motor Capacity Vs Load

    Keep in mind that it also depends on what you are actually driving. For a pump, for example, the pump curve would give you all the info you need in terms of load requirements etc.
  7. jasonf987

    Do motors get "tired"?

    I have had a similar problem in my plant, we found that the speed of the motor was too high which in turn affected the torque we needed. We replaced our 6 pole motor with a 4 pole one which increased the avaialable torque. we also needed to include some supports for the screw as due to the...
  8. jasonf987

    What is fail-safe design of switchgear control and relaying

    Fail safe itself refers to a safe condition being achieved under failed conditions. This can vary depending on the application, just ask yourself, from a safety point of view what condition must occur should there be a failed condition? This will enable you to then decide on how the system...
  9. jasonf987

    Kamyr Low Pressure Feeder

    Afternoon Gents, I am attempting to locate a 2nd hand "600 litre, Kamyr Low pressure feeder" still in good condition and am having no luck at the moment. can anyone direct me to a supplier or website which can assist me in locating one? Thanks.
  10. jasonf987

    Drive power query

    Thanks all for your replies, the drives are in a controlled environment, which includes air conditioning, air purification and room pressurization. We monitored the power quality on start up and there were no surges which occurred, while the supply was within the required range.
  11. jasonf987

    Drive power query

    Hi gents, We have a number of ABB AC drives in my mill. Having had a recent shut for 4 weeks we are now experiencing a number of drive related problems a few days after starting up eg: Power Caps blowing, control cards being damaged and needing to be changed etc. With consistant powering down...
  12. jasonf987

    Marks on bearing

    Hey Feg, if it came out of your stores and gave problems right away then it might be worth checking with them if they are storing the motors correctly and rotating the shafts as often as they should to prevent any bearing damage from occuring.
  13. jasonf987

    Eddy current query

    Morning Gents, i have a 3 phase, 400V AC system. i want to use two 185mm single core cables per phase in the terminal box, i am however concerned about eddy current. should the gland plate be made from a non metallic substance e.g bakalite and what is the minimum distance between the cables to...
  14. jasonf987

    running wet tranformer dry

    edison123, purely an indication of the oil changing colour to the next level. Belive it or not i have actually been challenged on the fact that the oil was not exactly the correct colour to warrant concern.
  15. jasonf987

    running wet tranformer dry

    Here is a bsaic colour chart to look at, which will give you a rough indication on what colour your oil should be and what it tells you of the oil conditionhttp://files.engineering.com/getfile.aspx?folder=d6cf6adc-cbea-4703-b333-9990a029e8f4&file=Oil_Colour_Chart.doc
  16. jasonf987

    Can a ball bearing destroy a refiner plate?

    When the plates were inspected prior to commissioning there was no ball bearing present, it seems to be a foreign body. From the evidence found it is our opinion that the centre locking cap screw securing the drive sleeve of the rotating disc to the shaft was not tightened properly, this in-turn...
  17. jasonf987

    Can a ball bearing destroy a refiner plate?

    Afternoon Gents, We had a recent failure of one of our refiners, which literally destroyed the refiner plates. upon closer inspection we found a tiny ball bearing lodged in the pieces of the plate. our supplier is adament it caused the failure, i however doubt it. there are no signs of rubbing...
  18. jasonf987

    running wet tranformer dry

    Mineral oil is the most common insulating medium and provides four functions that contribute to the operation of a transformer: •Dielectric strength – acts as a dielectric and insulating material. •Heat Transfer – acts as a cooling medium. •Protection – acts as a barrier between the paper and...
  19. jasonf987

    220vac 1p to 110vac 1p

    come now, simple answer...use a transformer! we all know the reason for the ground wire and it is def not there to carry your load.
  20. jasonf987

    annual cost of electric motor

    are you charged different tariffs for different periods throughout the year? (summer vs winter tariff) if so then it might be an easier "sell" to justify running it in the period where your electricity costs would most benefit your goal.