  1. bundy

    BMS reading for chiller

    hi sifox, just need to clarify something, what does Evap.range stand for ? evap refigerant temp ? thanks.
  2. bundy

    BMS reading for chiller

    hi, does any experience this problem before : On the BMS/BAS monitor screen, the chiller tonnage is X ton. but when i used the formulea ton= (16*flow(l/s)*Delta T)/24, the value is often different ? This is due to equipment calibration out. I yet to ask my BMS guy wat wrong ? Is there a...
  3. bundy

    ventilation design for a 25 meter indoor range

    The main purpose of the ventilation is to remove lead fume and dust at the bullet catcher area, and at the same time provide a control environment for the shooters.
  4. bundy

    chiller plant operation sequence

    i was told that the Air handling unit will need to start first before the starting of the CHiller. As there could be a possible surge/trip if the chiller experience no loading ? Anyone got experience in the control of chiller starting sequence using bAS software ?
  5. bundy

    chiller plant operation sequence

    hi All, Can someone advise me what is the normal operating sequence of the cooling tower, condenser Pump, Chiller water pump, chiller and AHU. Which equipment should start first ? thanks
  6. bundy

    converting HP to BTU

    Hi All, just a question, my fren told me you can not do a direct conversion for a split unit air con compressor from horsepower to BTU. Can any one advise. For example to convert 5HP for a VRV system to BTU. thanks
  7. bundy

    ventilation design for a 25 meter indoor range

    hi, The both designs had an extraction system at the bullet trap area fit with HEPA filter. I am just wondering how effective is the heat recovery method in of the the design. Is here other design which i can make reference to ? Will do a search on the internet too. thanks
  8. bundy

    ventilation design for a 25 meter indoor range

    Hi, all I currently reviewing an indoor range ventilation design. The consultant had proposed an supply/extraction system with and mixer box and dehumidifer system I had another consultant which provide me, an supply and extraction system with an run around coil; heat recovery system. Any...
  9. bundy

    AHU pipe connections

    hi Anyone have a good diagram of a typical valves connection of the chill water supply and return to the cooling coil. thanks can email to bundywu@yahoo.com