Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  1. Hipp53

    Finding RF and RM in implicit dynamic seismic analysis

    I have a cantilevered pipe-like structure modeled with shell elements and it is subjected to a seismic load using an implicit dynamic step. I have applied the acceleration to the bottom of the pipe using a boundary condition. In order to produce movement, I have released the transitional BC in...
  2. Hipp53

    ABAQUS Sequentially coupled thermal stress analysis-step type

    I am performing a sequentially coupled thermal stress analysis on a concrete slab. I have the heat transfer portion done and am experiencing some convergence difficulties with the stress analysis portion. My question is, should I use a static or dynamic step when reading the heat transfer into...
  3. Hipp53

    various temperature in shell element

    Mehrafarid, I am trying to model something very similar to your discussion on various temp. in shell element for a research project. I looked at your slab model and I have a question regarding the rebar. As you know, you can not use rebar in heat transfer analysis. I see that you neglected it in...