Hi guys, thank you very much. You both helped me a lot.
Till now I have already seen fuel gas pressure reduction but not that big one(from 67 bara to 7 bara).
The method of heating the fuel gas in the U-tube heat exchanger is a great idea. I was thinking about steam tracing of all the system...
Hi,
does anyone know how do I reduce fuel gas pressure from 67 bara to 7 bara???
Do I need any special led down stations, special valves, vessels...??
Thank you,
jana
Thank you for your reply.
I am searching for opinions. I normally do not design relief valves in Claus reheaters. But last time I had a customer who insisted on their instalation. That made me curious.
Hi,
does anybody have an experience with installation of relief valve on the Acid Gas Preheater (in front of the second Claus reactor)? I would like to know if you find necessary to install it.
Thank you,
Jana
Hi,
can anybody share with me his / her experience with relief valves on the Acid gas preheaters in Claus unit?
Is their installation really necessary? Claus unit is 'opened unit'. That is why I do not see a big reason to install them.
Thank you,
jana