Hello people.
I have a small question regarding the chloride limits for Super Duplex stainless steel for sour service in accordance with ISO 15159-3 Annex A.
Table 24 stipulates that Super Duplex can be used at any chloride concentration that:
“Occurs in production environment”
I would like...
I would like to second what brimmer says and recommend the ASME FFS-1 (API 579) standards as a way to evaluate the corrosion dammage. This standard will provide a less conservative approach as well as provide a solid framework for the assessment.
Also my experience with metal loss corrosion is...
Yes saying PSV i meen the choke valve. sorry for the confusion.
I haev rechecket the ISO 15156/NACE H2S limitations and the 5 ppm H2S will result in sour service at 760 Bar but within the allowable limitations for Super Duplex SS.
I have specifyed NORSOK M-501 paint codes as to avoid SCC...
thank you strider6.
I'll be reading you'r references as well as taking a look at NORSOK M-001 again. From the process information i have available elemental sulphur will not be a problem, neither will the H2S partial pressure (even before the PSV)
- Klaus Truelsen
I may have been somwhat unclear about the application of the material.
The materials in question is to be used for process piping in the meantioned process parameters.
I have performed a CO2 corrosino rate prediction based on the C. de Waard model and im predicting 4-4,5 mm/year corrosion...
Good day.
I’m a newly graduated engineer and I work in the Oil & Gas industry in Denmark. I have been tasked with performing a material selection for an offshore oil facility in the North Sea. As part of this assignment I have access to the predicted flow parameters and I must admit that the...