Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

  • Congratulations waross on being selected by the Eng-Tips community for having the most helpful posts in the forums last week. Way to Go!

Search results for query: *

  • Users: TomOC
  • Order by date
  1. TomOC

    Molsieve 13X-APG 1/16"

    MolSieve manufacturers can be a good source for this type of information.
  2. TomOC

    "wet" regeneration gas molsieve ASU

    Moisture does not destroy the molsieve. It is designed to take water out as well as carbon dioxide. Sometimes the molsieve can be brought back through elevated regen temp. Do you have the possibility of using higher steam temp? MolSieve can be also baked-out at the factory in some cases...
  3. TomOC

    Hydrogen Humidifier

    68 F dpt is actually maximum capability. required control range is actually between 46f and 54f dpt.
  4. TomOC

    Hydrogen Humidifier

    Flow is 2,000 SCFH Normal (3,000 SCFH max) Supply Pressure is 4 psig (min) to 17 psig (max..which can be regulated down further) at Temperature of 68 F and feed dew point in range of -40f to -94f. Require that the h2 gas be delivered at constant flow with +68f dew point (assuming +/- 10% water...
  5. TomOC

    Hydrogen Humidifier

    Looking for help in selecting best way to add moisture to dry hydrogen gas to reach and maintain a desired dew point.
  6. TomOC

    Dessicant Specifications

    You can ask for typical performance data (of the dessicant material) from activated alumina vendors. Specifically you should ask for isotherms, to ensure that dessicant material performs to requirements.
  7. TomOC

    Bead versus Pellet form of molecular sieve

    For a given size pellets tend to have a higher pressure drop. When sizing vessels beads allow smaller diameters because they are harder to fluidize. Tom
  8. TomOC

    Air Dryer Design

    You should be able to get some basic sizing information from adsorbent manufacturers such as Alcoa and UOP. Both of these companies are interested in selling their activated alumina for this application and normally give out this info for free. If you need lower dewpoints molecular sieves by...
  9. TomOC

    Process Selection for removal of CO2, H2S & H2O from Natural Gas Well

    Suggestions on process selection preferences for purification(Removal of CO2, H2S and H2O)from natural gas well. Have heard of difficulties with membranes and that MDEA is the latest hottest way to go if scrubbing. Temperature Rating : 130 - 140 degree Farenheit Pressure Rating : 1200 - 1300...

Part and Inventory Search

Back
Top