Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  • Users: csd72
  • Order by date
  1. csd72

    Elevated concrete floor: shore it up or demo?

    Are you sure that is concrete on top? Could be self levelling screed, it is difficult to tell the difference with an untrained eye. I expect those joist would have a visible sage with that amount of weight on it.
  2. csd72

    Hello again

    Hello everyone, been a long time gone but I still recognise some of your tags.
  3. csd72

    AS3600 2017 Draft

    This goes back to tilt up and precast panels which are mostly singularly reinforced. There has been testing over the years to prove that they are more robust than you may think. Not all buildings are affected by the earthquake provisions.
  4. csd72

    Punching shear v Beam shear capacity comparison

    In most codes beams shear is given a higher factor of safety than slab shear I believe the theory is that you are unlikely to have poor concrete across the full shear width of a slab whereas it is more likely on a narrow beam.
  5. csd72

    Checking calculations

    Most serious failures do not occur because the member is not quite strong enough, most occur because of something fundamentally wrong with the structural scheme or with the way it has been installed. Conservatism will not negate this only checking of the design will negate this. Even with...
  6. csd72

    6m Deep Basement

    6m is quite tall for a single floor so you would probably need 600mm diameter secant or quite chunky sheet piles. Also look at the available space you have to surrounding structures and the required clearance you need for each. Both options would need to be propped during construction though I...
  7. csd72

    Deflection limits for a composite transfer beam

    Rapt, Thanks, that was the direction that I was thinking and was concerned about, particularly for a pt slab above. We have resolved the main issue of the moments by letting the transfer slab sag under the weight of the wet concrete. This is not perfect but I had three structural consultants...
  8. csd72

    Deflection limits for a composite transfer beam

    Thanks, That is about where I am coming from. The transfer beam that I am looking at has a 2.25 inch total deflection in a 42foot span with the coluumns supporting the middle of the PT slab above. The design consultants just dont get my concerns, they keep stating that it is 'to code' but the...
  9. csd72

    Deflection limits for a composite transfer beam

    What limits would people be looking to design a transfer beam that supports a concrete column and post tensioned flat slab at the level above and a reinforced concrete slab at its wown level. I have a consultant that has designed a transfer beam that is no stiffer than your average floor beam...
  10. csd72

    Turning a Dynamic Load into a Static Load

    englisa, I think you are missing the point here. Calculate the deflection from a one pound point load and the inverse gives you a spring constant. From that you can determine how much force is exerted for each mm of deflection and then calculate the total impulse required and therefore tha...
  11. csd72

    Tall Wood Buildings

    Lutfi, Actually, steel loses its strength faster than large sections of timber char so sometimes the mental picture of wood burning is counterintuitive to the reality.
  12. csd72

    Forces Acting on a Pipe

    What happens if you get oscillations in the cables and those on one side go a little slack for a split second, what stops the rod from rotating and the cables slipping off? This is not a detail that I would feel comfortable with.
  13. csd72

    Vibrating wood floor system

    rheim, The atc put out a guidance note on timber vibration though I am not sure how helpful it would be. The fundamental are still the same for all materials so I suggest that you research vibration in general to get a handle on things. Modern research has shown that the key is usually the...
  14. csd72

    Increase axial capacity of existing slender concrete column

    Eng32, I would suggest you do a google search on seismic retrofit, they do this sort of thing all the time. You may consider a steel jacket.
  15. csd72

    Robot, Risa3d or another

    I used robot for a short while and did not find it very user friendly.
  16. csd72

    Double Cantilevered Canopy

    Ailmar, A few things to check: Firstly with that moment connection detail you have a long buckling length for the plate at the compression flange so you need to check that it has sufficient buckling capacity. The uneven configuration will result in an uneven front under dead load so you may...
  17. csd72

    call me crazy

    naah, I would only suggest you hire a structural engineer if you dont want it to fall down. Seriously, there are a lot of considerations here which only an SE would truly understand.
  18. csd72

    Shallow Foundation for a Concrete Column

    and its even worse than that since the bridge must span over a void and your sliding force acts toward this void. I suggest you look at the anchorages as hokie has suggested or the whole thing could end up the the river.
  19. csd72

    Increasing existing concrete slab thickness

    Nothing that a good scheme of needling and underpinning wont fix. I agree wih the others, replacing top and bottom slabs wont fix the root cause and will normally cost more money.
  20. csd72

    Implicit Safety Factors in Wood Design

    Hickory, I read all your posts and I think you make some very interesting points, both political and technical. In my few years I spent in the US I did find that the government seemed to be much more pro big business than most other places. I also think the point about the effect of bearing...
Back
Top