As sentenced in DNV,I interpreted the maximum 3mm is allowed any length
and over 3mm is classified as excess.
Same for "Cap reinforcement(for single sided welds)height given .2t but Max.4mm
Thank you so much for your time Shane. Much appreciated
Regards.
Hi Friends,
Help me if you can. I am qualifying welders on a 32 inch 39 thick, "Single V Butt"
Gas line pipe and referring acceptance criteria- DNV-OS-F101 2010 for Root penetration
"Table-4 Acceptance criteria for visual and surface method testing of welds"
"Root penetration (Single side...
Dear Friends,
It would be much appreciated if any one could answer me on below
I am qualified on a 6inch 12mm thick cs X65 pipe 5G GMAW semi automatic machine Down Hill
What would be the range of my qualification approved
Minimum and maximum thickness and diameter
Thanks