Sure, here you go.
The filler metal is ER NiCrMo-13 (alloy 59)
Root and hot pass are made by manual GTAW, fill and cap by automatic GTAW.
The aim is to write a production WPS for a partial penetration joint between CS and DSS using automatic GTAW only. In this configuration the CS side will...
Dear all,
if I have an ASME IX PQR qualified welding a P-No.1 material with a 3 mm root made of inconel 625 by weld overlay to a P-No.10H material (BW full penetration) am I allowed to write a WPS for a partial penetration joint P-No.1 to P-No.10H without inconel 625 root on the carbon steel...