Eng-Tips is the largest engineering community on the Internet

Intelligent Work Forums for Engineering Professionals

Search results for query: *

  1. Mfakhfekh

    Conformity to EN1090-2

    Hello When the execution specification sent by the client doesn't consider Additional information and options (4.1.1), what shall the manufacturer do? Who is responsible for ensuring that the execution specification is complete?
  2. Mfakhfekh

    Undercut

    The undercut is identified all the long of the weld but with maximum depth 0.8mm measured by weld gauge and strip standard gap gauge.
  3. Mfakhfekh

    Undercut

    Thanks UW-35 and the interpretation forwarded by David confirm that Code accepts the undercut regardless of its length provided the depth is less than 1mm or 10%. Since the purpose of the Code is safety, Comity should know that this defect is not harmful to the pv integrity before issuing the...
  4. Mfakhfekh

    Undercut

    r6155 The weld having that undercut is acceptable by visual as per Code. Why should the welding process be investigated?
  5. Mfakhfekh

    Undercut

    Thank you all.
  6. Mfakhfekh

    Undercut

    Thanks This case is for carbon steel sa516gr70 pressure vessel nominal thickness of shell 20mm
  7. Mfakhfekh

    Undercut

    Un undercut having depth 0.8mm is identified at all the long of a butt weld at the toe. Is it acceptable per ASME VIII Div 1?
  8. Mfakhfekh

    ASME VIII-1 Appendix 2 Flange Stresses

    Look in the document ASME PTB-4-13. It provides very good explanations to Code rules with some corrected exercises. (see exercise 4.16)